550 kW generators: compare prices, specs and fuel costs across brands

In GenTrak's catalog, a 550 kW generator costs about $150,000 new and $31,500 to $112,500 used, depending on hours. We list models at this size from Caterpillar, Cummins, Kohler, Taylor Power Systems, Blue Star, MTU, and HiPower.

Catalog data compiled November 8, 2026. Prices are before installation and delivery, and accurate to about 20 to 30 percent on industrial units.

Models
13
Brands
7
Typical new price
$150,000
Typical used price
$31,500 to $112,500

Running and moving a 550 kW generator

Fuel burn at 75% load
28.7 gal of diesel per hour
Freight, about 500 miles
$3,450 to $6,700
Shipping weight about 13,620 lb, including unloading at delivery
Median price per kW
$273

Fuel burn is a typical engineering value for this rating. Freight is a ballpark, not a carrier quote.

How much does a 550 kW generator cost?

New and zero-hour prices at this size, split by fuel and by brand. 11 models of 13 have a price.

FuelModelsRangeMedian
Diesel9$143,000 to $210,000$143,000
Gas2$186,000 to $214,000$200,000
BrandModelsRangeMedian
Caterpillar2$143,000$143,000
Cummins2$143,000 to $186,000$164,500
Kohler1$143,000$143,000
Taylor Power Systems1$143,000$143,000
Blue Star4$150,000 to $214,000$180,000
MTU1$157,500$157,500
HiPower1$275,000$275,000

What is a used 550 kW generator worth?

Typical fair market value for a maintained unit that runs and has service records. Each row is the median of the 11 models at this size, and the range is the lowest and highest model.

Hours on meterTypical value% of new
1–250 hrs$112,50075%
251–500 hrs$105,00070%
501–1,000 hrs$94,50063%
1,001–2,000 hrs$78,00052%
2,001–4,000 hrs$63,00042%
4,001–7,500 hrs$51,00034%
7,501–10,000 hrs$41,00027%
10,000+ hrs$31,50021%

Value depends on the depreciation class of each model. How we price, or run your own unit through Price a Gen.

Which generators are rated 550 kW?

Models for permanent installation, plus mobile and portable units below. Sorted by price, lowest first.

6 brands. Tap a brand to see its models.

Mobile, towable and portable at 550 kW

2 brands. Tap a brand to see its models.

Estimated value is GenTrak's estimate of fair market value where a list price is not published. Voltage and phase are as listed by the manufacturer, and many models are configurable, so confirm on the spec sheet before you buy.

What can a 550 kW generator run?

Plan on about 440 kW of steady load. This is the working range for commercial buildings, farms, water plants and small manufacturing.

  • Around 55,000 sq. ft. of commercial space at a typical 8 watts per square foot, or a mid-size building with an elevator and cooling.
  • Motor loads up to roughly 489 hp running together, which is why starting method (across the line, soft start or drive) matters here.
  • A water or wastewater station, grain facility or dairy where the pumps drive the size.

Electrical and fuel at 550 kW

Full-load current
1,908 A at 208 V three-phase and 827 A at 480 V three-phase
Diesel
21 gal/hr at half load, 36.9 gal/hr full
Natural gas
3,328 ft³/hr at half load, 6,050 ft³/hr full

Typical values, not manufacturer ratings. Cost to run turns the burn rate into dollars per hour.

Diesel vs. gas at 550 kW

Both fuels are available at this rating in our catalog, so here is how they compare.

DieselGas
Models92
Median new price$143,000$200,000
Price per kW$260$364
Fuel at half load21 gal/hr3,328 ft³/hr
Fuel at full load36.9 gal/hr6,050 ft³/hr

Gas here means natural gas. Diesel is stored on site and suits long outages. Gas avoids a fuel tank but depends on the utility line or a propane supply.

Buying checklist for a 550 kW generator

Voltage and phase

Confirm 120/208, 120/240, 277/480 or 347/600 V, and single or three-phase, before you compare prices. Many models are configurable.

Enclosure

Open, weather-protected or sound-attenuated. Sound-attenuated costs more and adds size, and some sites need it for noise limits.

Emissions and air permit

Rules differ for emergency standby and for prime or peak-shaving use, and vary by state. Ask your state air office before you buy.

Transfer switch (ATS)

Size the ATS to the load and the service, not just the generator. Plan for it in the budget.

Freight and install

A unit this size usually ships by flatbed and needs a crane or forklift, a pad and conduit.

Fuel supply

Decide between on-site diesel storage and a gas line before you pick a model.

Get a delivered number with the freight estimator. Hardwired installs need a licensed electrician, so see licensed electricians.

State rules

Permits, electrician licensing, air quality and fuel storage are set by your state and often your county. Look up the regulator for your state before you install a 550 kW generator.

State generator regulators →

Where to buy a 550 kW generator

Official dealer locators

Ask a dealer about lead times, parts and who handles warranty service.

Previous and next size

Size 199 of 302. See every size or browse all 500 to 1,000 kW generators.

Common questions

How much does a 550 kW generator cost?

In our catalog, a 550 kW generator runs from $143,000 to $214,000 new, with a median of $150,000 (about $273 per kW). Used units typically sell for $31,500 to $112,500 used. Installation, freight, fuel supply and permits are usually extra, and industrial estimates are accurate to about 20 to 30 percent.

What can a 550 kW generator run?

Plan on about 440 kW of steady load. This is the working range for commercial buildings, farms, water plants and small manufacturing. Around 55,000 sq. ft. of commercial space at a typical 8 watts per square foot, or a mid-size building with an elevator and cooling. Motor loads up to roughly 489 hp running together, which is why starting method (across the line, soft start or drive) matters here. A water or wastewater station, grain facility or dairy where the pumps drive the size.

How much fuel does a 550 kW generator use?

Diesel: about 21 gal per hour at half load and 36.9 gal per hour at full load. Natural gas: about 3,328 ft³ per hour at half load and 6,050 ft³ per hour at full load. These are typical engineering values, so check the spec sheet of the exact unit. The Fuel Hub turns them into dollars per hour.

What size breaker and wire does a 550 kW generator need?

Full-load current is about 1,908 A at 208 V three-phase and 827 A at 480 V three-phase. A licensed electrician sizes the breaker, conductors and transfer equipment from the nameplate and local code, so use these numbers only for planning.

Is a 550 kW generator better as diesel or gas?

We list 9 diesel models and 2 gas models at 550 kW. Diesel median is $143,000 and gas is $200,000. Diesel stores on site and holds up under long runs; gas avoids on-site fuel storage but depends on the utility or a propane tank. The comparison table above shows both side by side.

Not sure of the size?

Add up your loads and see the running and starting watts you need.

Open →

Value or sell one

Estimate fair market value from hours, age and condition.

Open →

Sellers we trust

National sellers and each brand's dealer locator.

Open →