Generator Size Calculator: How Many Watts Do You Need?
To size a generator, add up the running watts of everything you want to power, add the biggest startup surge, then leave about 15% headroom. Pick your appliances below and the calculator does that math for you.
Updated November 2026.
Kitchen (26)
- 1
Heating and cooling (24)
- 1
Water and plumbing (13)
Laundry and cleaning (6)
Lights, TV and entertainment (8)
- 1
- 1
Home office (5)
Medical and comfort (8)
Garage and workshop (12)
Outdoor and pool (9)
Your result
Running watts
2,025
Peak with surge
3,525
Biggest startup surge: Refrigerator, adding 1,500 W for a few seconds.
Smallest size with 15% headroom
Mid-size inverter
Rated at least 3,000 W running, 3,800 W starting.
Handles a fridge plus one bigger motor, like a sump pump or window AC.
79 models in our catalog fit
Each runs at least 2,330 W and handles a 3,530 W startup surge. Smallest first.
GAW180HEANC2180 A DC weld; 3 kW ACNew$4,785
List or retailUsed$2,500
Used price range, 501 to 1,000 hrs$1,900$3,150
iQ3800 Dual Fuel – 8944 (G0089440), 49ST3,800 W startingNew$1,029
List or retailUsed$390
Used price range, 501 to 1,000 hrs$295$490
iQ3800 Dual Fuel – 8946 (G0089460), 50ST3,800 W startingNew$1,269
List or retailUsed$480
Used price range, 501 to 1,000 hrs$360$600
3500 Watt Portable (030736)4,375 W starting / 3,500 W runningNew$774
List or retailUsed$290
Used price range, 501 to 1,000 hrs$220$365
Estimate only. A licensed electrician should confirm the size before you buy.
How the generator size calculation works
- 1
Add the running watts
List every appliance you want to run at the same time and add their running watts. Check the nameplate or manual, or use the typical values in the chart below.
- 2
Add the biggest startup surge
Motors pull extra power for a few seconds as they start. They rarely start together, so add only the largest startup surge, the difference between starting and running watts.
- 3
Leave headroom
Choose the smallest generator rated above running watts plus 15% for a home, or 25% for a business, and above your peak with surge.
The formula
Needed running watts = total running watts × 1.15
Needed peak watts = total running watts + largest startup surge
Generator sizes are listed by running (rated) watts, with a higher starting (max) rating for short surges. 1,000 watts = 1 kW.
Worked examples
Three common home setups, run through the same calculator.
Outage essentials
Keeps food cold, the house warm and the lights on.
- Refrigerator700 W
- Chest freezer500 W
- Gas furnace fan (1/2 HP)875 W
- Lights (20 LED bulbs)200 W
- TV and internet router250 W
- Phone and laptop charging100 W
- Running
- 2,625 W
- Peak with surge
- 4,125 W
Size: Large portable (at least 5,500 W running).
Rural home with a well and sump pump
Adds the two pumps that matter most when the power is out.
- Refrigerator700 W
- Gas furnace fan (1/2 HP)875 W
- Well pump (1/2 HP)1,000 W
- Sump pump (1/2 HP)1,050 W
- Lights (20 LED bulbs)200 W
- Microwave1,000 W
- Coffee maker1,000 W
- Running
- 5,825 W
- Peak with surge
- 7,325 W
Size: Extra-large portable (at least 7,500 W running). Includes 240V loads.
Home with central AC
Central air is the load that pushes most homes toward standby.
- Refrigerator700 W
- Chest freezer500 W
- Gas furnace fan (1/2 HP)875 W
- Central AC (2 ton)2,500 W
- Well pump (1/2 HP)1,000 W
- Sump pump (1/2 HP)1,050 W
- Lights (20 LED bulbs)200 W
- TV and internet router250 W
- Microwave1,000 W
- Running
- 8,075 W
- Peak with surge
- 13,075 W
Size: home standby, more than 7,500 W running. Includes 240V loads.
Appliance wattage chart
Typical running and starting watts for common home appliances. Your own equipment may differ, so check the nameplate when you can. A dash means no startup surge.
| Appliance | Running | Starting |
|---|---|---|
| Refrigerator | 700 W | 2,200 W |
| French-door or side-by-side fridge | 800 W | 2,400 W |
| Mini fridge | 100 W | 350 W |
| Chest freezer | 500 W | 1,500 W |
| Upright freezer | 700 W | 2,100 W |
| Microwave | 1,000 W | – |
| Coffee maker | 1,000 W | – |
| Espresso machine | 1,300 W | – |
| Electric kettle | 1,500 W | – |
| Toaster | 850 W | – |
| Toaster oven | 1,200 W | – |
| Air fryer | 1,500 W | – |
| Slow cooker | 250 W | – |
| Electric pressure cooker | 1,000 W | – |
| Rice cooker | 700 W | – |
| Blender | 400 W | 850 W |
| Stand mixer | 300 W | 600 W |
| Electric griddle or skillet | 1,500 W | – |
| Electric stove, one burner (240V) | 1,500 W | – |
| Electric range with oven (240V) | 5,000 W | – |
| Electric wall oven (240V) | 3,000 W | – |
| Dishwasher | 1,500 W | – |
| Garbage disposal (1/2 HP) | 500 W | 1,500 W |
| Range hood fan | 150 W | – |
| Wine or beverage cooler | 100 W | 300 W |
| Countertop ice maker | 150 W | 450 W |
| Appliance | Running | Starting |
|---|---|---|
| Gas furnace fan (1/2 HP) | 875 W | 2,350 W |
| Gas furnace fan (1/3 HP) | 700 W | 1,400 W |
| Furnace blower (3/4 HP) | 1,100 W | 3,000 W |
| Boiler pump | 300 W | 900 W |
| Heat pump (2 ton) (240V) | 2,500 W | 7,500 W |
| Heat pump (3 ton) (240V) | 3,500 W | 10,000 W |
| Central AC (2 ton) (240V) | 2,500 W | 7,500 W |
| Central AC (3 ton) (240V) | 3,500 W | 10,000 W |
| Central AC (4 ton) (240V) | 4,700 W | 13,000 W |
| Central AC (5 ton) (240V) | 6,000 W | 16,000 W |
| Window AC (5,000 BTU) | 500 W | 1,300 W |
| Window AC (10,000 BTU) | 1,200 W | 3,600 W |
| Window AC (15,000 BTU) | 1,500 W | 4,500 W |
| Portable AC (12,000 BTU) | 1,200 W | 3,600 W |
| Ductless mini-split (12,000 BTU) | 1,000 W | 1,300 W |
| Space heater | 1,500 W | – |
| Electric baseboard heater (1,000 W) (240V) | 1,000 W | – |
| Pellet stove | 120 W | 500 W |
| Ceiling fan | 75 W | – |
| Box or tower fan | 100 W | – |
| Dehumidifier | 600 W | 1,800 W |
| Humidifier | 200 W | – |
| Attic or whole-house fan | 400 W | 900 W |
| Electric blanket | 200 W | – |
| Appliance | Running | Starting |
|---|---|---|
| Sump pump (1/3 HP) | 800 W | 1,300 W |
| Sump pump (1/2 HP) | 1,050 W | 2,150 W |
| Sump pump (3/4 HP) | 1,300 W | 2,900 W |
| Well pump (1/2 HP) (240V) | 1,000 W | 2,100 W |
| Well pump (3/4 HP) (240V) | 1,500 W | 3,000 W |
| Well pump (1 HP) (240V) | 2,000 W | 4,000 W |
| Sewage ejector pump (1/2 HP) | 1,000 W | 2,000 W |
| Electric water heater (240V) | 4,000 W | – |
| Heat pump water heater (240V) | 550 W | 1,100 W |
| Tankless electric water heater (whole home) (240V) | 18,000 W | – |
| Hot water recirculating pump | 100 W | 300 W |
| Water softener | 50 W | – |
| Pipe heat tape | 100 W | – |
| Appliance | Running | Starting |
|---|---|---|
| Washing machine | 1,150 W | 2,250 W |
| Electric dryer (240V) | 5,400 W | 6,750 W |
| Gas dryer | 700 W | 1,800 W |
| Clothes iron | 1,200 W | – |
| Vacuum cleaner | 1,200 W | 1,500 W |
| Robot vacuum (charging) | 50 W | – |
| Appliance | Running | Starting |
|---|---|---|
| Lights (10 LED bulbs) | 100 W | – |
| Lights (20 LED bulbs) | 200 W | – |
| Incandescent lights (5 × 60 W) | 300 W | – |
| TV and internet router | 250 W | – |
| Large TV (65 in. or bigger) | 200 W | – |
| Gaming console | 200 W | – |
| Sound system or soundbar | 150 W | – |
| Aquarium (heater, pump and light) | 200 W | – |
| Appliance | Running | Starting |
|---|---|---|
| Phone and laptop charging | 100 W | – |
| Desktop computer and monitor | 400 W | – |
| Laser printer | 600 W | – |
| Inkjet printer | 50 W | – |
| Security cameras and alarm | 100 W | – |
| Appliance | Running | Starting |
|---|---|---|
| Medical device (CPAP or oxygen) | 350 W | – |
| CPAP machine | 60 W | – |
| Home oxygen concentrator | 600 W | 1,200 W |
| Medicine fridge | 100 W | 300 W |
| Power wheelchair or scooter charger | 300 W | – |
| Electric hospital bed | 200 W | 400 W |
| Stair lift | 400 W | 1,200 W |
| Hair dryer | 1,500 W | – |
| Appliance | Running | Starting |
|---|---|---|
| Garage door opener (1/2 HP) | 725 W | 1,400 W |
| Garage refrigerator | 700 W | 2,200 W |
| Air compressor (1 HP) | 1,600 W | 4,500 W |
| Circular saw | 1,400 W | 2,300 W |
| Miter saw | 1,800 W | 3,600 W |
| Table saw (10 in.) | 1,800 W | 4,500 W |
| Electric drill | 600 W | 900 W |
| Shop vacuum | 1,000 W | 2,000 W |
| Bench grinder | 400 W | 1,200 W |
| Battery tool chargers | 150 W | – |
| EV charger, Level 1 (120V) | 1,440 W | – |
| EV charger, Level 2 (240V) (240V) | 7,200 W | – |
| Appliance | Running | Starting |
|---|---|---|
| Pool pump (1 HP) (240V) | 1,500 W | 3,500 W |
| Pool pump (1.5 HP) (240V) | 2,000 W | 4,500 W |
| Hot tub (heater and pump) (240V) | 6,000 W | 8,000 W |
| Pond or fountain pump | 150 W | 300 W |
| Outdoor and landscape lights | 200 W | – |
| Electric pressure washer | 1,800 W | 3,500 W |
| Electric leaf blower | 1,200 W | – |
| Electric hedge trimmer | 500 W | – |
| Driveway gate opener | 400 W | 800 W |
After you have your number
Compare matching models
See every model in our catalog that fits, with list prices, used values by hours, and fuel types.
Open →Read the sizing guide
A longer walk-through of running watts, startup surge and headroom, with the common mistakes.
Open →Price a used generator
Estimate fair market value from hours, age and condition if you're buying or selling used.
Open →A generator connected to your building's wiring needs a transfer switch or interlock kit installed by a licensed electrician. Never plug a generator into a wall outlet, and never run one indoors or in a garage, because of carbon monoxide. See the emergency preparedness checklist.
Generator sizing questions
How do I calculate what size generator I need?
Add up the running watts of everything you want to power at the same time. Find the single biggest startup surge among your motors (like a fridge, sump pump or well pump) and add only that extra amount, because motors rarely all start at once. Then add about 15% headroom for a home or 25% for a business, and choose the smallest generator rated above both numbers.
What size generator do I need to run a house?
It depends on what you run. Outage essentials such as a fridge, freezer, furnace fan, lights and a TV usually fit a mid-size inverter or a large portable (roughly 3,000 to 5,500 running watts). Adding a well pump, sump pump and a few more loads moves you to the extra-large portable range. Running central AC, an electric range or a dryer usually means a permanent home standby generator. The calculator above shows where your own list lands.
What's the difference between running watts and starting watts?
Running watts are the steady power a generator supplies all the time. Starting (or surge) watts are the short burst a motor pulls for a few seconds when it starts. A generator needs enough running watts for everything on at once, plus enough surge capacity for the biggest motor starting.
Is a generator's kW rating the same as watts?
One kilowatt (kW) is 1,000 watts, so a 7.5 kW generator supplies 7,500 watts. Some labels list kVA instead, which is apparent power. For household loads, multiply kVA by about 0.8 to estimate usable kW. Always check whether a rating is the running (rated) or the maximum (starting) output.
Can a 5,000-watt generator run a whole house?
Rarely, unless the home is small and you leave out the big loads. A 5,000-watt generator can run essentials and one larger motor, but central AC, an electric range, an electric dryer or an electric water heater can each use several thousand watts on their own. Use the calculator to see your actual total.
Do I need a 240-volt generator?
Yes if you want to run anything that uses 240 volts, such as a well pump, central AC, an electric dryer or range, or a hot tub. Many small inverter generators only have 120-volt outlets. A 240-volt generator also needs a transfer switch or interlock kit installed by a licensed electrician.
Should I size up for the future?
A little. The calculator already adds headroom so the generator isn't running at its limit. If you plan to add AC, an EV charger or a well, include them now, since moving up a size later usually means buying a new generator.
Do the wattages in your calculator apply to 50 Hz?
Appliance wattages are about the same on 50 Hz and 60 Hz, but the voltage and the appliances themselves differ by country. If you are sizing for 50 Hz, enter the nameplate wattage from your own equipment, then match the generator's frequency and voltage to where it will be used.
