240 kW generators: compare prices, specs and fuel costs across brands

In GenTrak's catalog, a 240 kW generator costs about $85,000 new and $18,000 to $64,000 used, depending on hours. We list models at this size from Cummins, Caterpillar, Gillette, and Multiquip.

Catalog data compiled November 8, 2026. Prices are before installation and delivery, and accurate to about 20 to 30 percent on industrial units.

Models
5
Brands
4
Typical new price
$85,000
Typical used price
$18,000 to $64,000

Running and moving a 240 kW generator

Fuel burn at 75% load
13.1 gal of diesel per hour
Freight, about 500 miles
$1,700 to $3,200
Shipping weight about 8,770 lb, including unloading at delivery
Median price per kW
$354

Fuel burn is a typical engineering value for this rating. Freight is a ballpark, not a carrier quote.

How much does a 240 kW generator cost?

New and zero-hour prices at this size, split by fuel and by brand. 3 models of 5 have a price.

FuelModelsRangeMedian
Diesel2$77,000 to $85,000$81,000
Gas1$105,500$105,500
BrandModelsRangeMedian
Cummins1$77,000$77,000
Caterpillar1$85,000$85,000
Gillette1$105,500$105,500
Multiquip1$122,000$122,000

What is a used 240 kW generator worth?

Typical fair market value for a maintained unit that runs and has service records. Each row is the median of the 3 models at this size, and the range is the lowest and highest model.

Hours on meterTypical value% of new
1–250 hrs$64,00075%
251–500 hrs$59,50070%
501–1,000 hrs$53,50063%
1,001–2,000 hrs$44,00052%
2,001–4,000 hrs$35,50042%
4,001–7,500 hrs$29,00034%
7,501–10,000 hrs$23,00027%
10,000+ hrs$18,00021%

Value depends on the depreciation class of each model. How we price, or run your own unit through Price a Gen.

Which generators are rated 240 kW?

Models for permanent installation, plus mobile and portable units below. Sorted by price, lowest first.

3 brands. Tap a brand to see its models.

Mobile, towable and portable at 240 kW

2 brands. Tap a brand to see its models.

Estimated value is GenTrak's estimate of fair market value where a list price is not published. Voltage and phase are as listed by the manufacturer, and many models are configurable, so confirm on the spec sheet before you buy.

What can a 240 kW generator run?

Plan on about 192 kW of steady load. This is the working range for commercial buildings, farms, water plants and small manufacturing.

  • Around 24,000 sq. ft. of commercial space at a typical 8 watts per square foot, or a mid-size building with an elevator and cooling.
  • Motor loads up to roughly 213 hp running together, which is why starting method (across the line, soft start or drive) matters here.
  • A water or wastewater station, grain facility or dairy where the pumps drive the size.

Electrical and fuel at 240 kW

Full-load current
833 A at 208 V three-phase and 361 A at 480 V three-phase
Diesel
9.6 gal/hr at half load, 16.8 gal/hr full
Natural gas
1,452 ft³/hr at half load, 2,640 ft³/hr full

Typical values, not manufacturer ratings. Cost to run turns the burn rate into dollars per hour.

Diesel vs. gas at 240 kW

Both fuels are available at this rating in our catalog, so here is how they compare.

DieselGas
Models21
Median new price$81,000$105,500
Price per kW$338$440
Fuel at half load9.6 gal/hr1,452 ft³/hr
Fuel at full load16.8 gal/hr2,640 ft³/hr

Gas here means natural gas. Diesel is stored on site and suits long outages. Gas avoids a fuel tank but depends on the utility line or a propane supply.

Buying checklist for a 240 kW generator

Voltage and phase

Confirm 120/208, 120/240, 277/480 or 347/600 V, and single or three-phase, before you compare prices. Many models are configurable.

Enclosure

Open, weather-protected or sound-attenuated. Sound-attenuated costs more and adds size, and some sites need it for noise limits.

Emissions and air permit

Rules differ for emergency standby and for prime or peak-shaving use, and vary by state. Ask your state air office before you buy.

Transfer switch (ATS)

Size the ATS to the load and the service, not just the generator. Plan for it in the budget.

Freight and install

A unit this size usually ships by flatbed and needs a crane or forklift, a pad and conduit.

Fuel supply

Decide between on-site diesel storage and a gas line before you pick a model.

Get a delivered number with the freight estimator. Hardwired installs need a licensed electrician, so see licensed electricians.

State rules

Permits, electrician licensing, air quality and fuel storage are set by your state and often your county. Look up the regulator for your state before you install a 240 kW generator.

State generator regulators →

Where to buy a 240 kW generator

Official dealer locators

Ask a dealer about lead times, parts and who handles warranty service.

Nearby sizes

240 kW is a less common rating, so only 5 models are listed here. The nearest sizes (225 kW to 260 kW) run about $334 per kW, so a nearby size is often a better match.

Size 159 of 302. See every size or browse all 100 to 250 kW generators.

Common questions

How much does a 240 kW generator cost?

In our catalog, a 240 kW generator runs from $77,000 to $105,500 new, with a median of $85,000 (about $354 per kW). Used units typically sell for $18,000 to $64,000 used. Installation, freight, fuel supply and permits are usually extra, and industrial estimates are accurate to about 20 to 30 percent.

What can a 240 kW generator run?

Plan on about 192 kW of steady load. This is the working range for commercial buildings, farms, water plants and small manufacturing. Around 24,000 sq. ft. of commercial space at a typical 8 watts per square foot, or a mid-size building with an elevator and cooling. Motor loads up to roughly 213 hp running together, which is why starting method (across the line, soft start or drive) matters here. A water or wastewater station, grain facility or dairy where the pumps drive the size.

How much fuel does a 240 kW generator use?

Diesel: about 9.6 gal per hour at half load and 16.8 gal per hour at full load. Natural gas: about 1,452 ft³ per hour at half load and 2,640 ft³ per hour at full load. These are typical engineering values, so check the spec sheet of the exact unit. The Fuel Hub turns them into dollars per hour.

What size breaker and wire does a 240 kW generator need?

Full-load current is about 833 A at 208 V three-phase and 361 A at 480 V three-phase. A licensed electrician sizes the breaker, conductors and transfer equipment from the nameplate and local code, so use these numbers only for planning.

Is a 240 kW generator better as diesel or gas?

We list 2 diesel models and 1 gas model at 240 kW. Diesel median is $81,000 and gas is $105,500. Diesel stores on site and holds up under long runs; gas avoids on-site fuel storage but depends on the utility or a propane tank. The comparison table above shows both side by side.

Not sure of the size?

Add up your loads and see the running and starting watts you need.

Open →

Value or sell one

Estimate fair market value from hours, age and condition.

Open →

Sellers we trust

National sellers and each brand's dealer locator.

Open →